Single-textile-reinforced hose for suction, case-drain, return and cooling circuits, built in one-, two- and three-braid return classes with crimped or clamped tails for low-pressure duty.
Reference image — production units follow the approved drawing and the specification table below.
Return and suction lines fail for different reasons than pressure lines. A return hose is routed long, kinked behind a boom and exposed to heat soak; a suction line gets a partial vacuum and collapses if the reinforcement was bought for pressure instead. We build both classes from hose with the reinforcement the duty needs, in the bore that keeps the flow velocity honest.
Sizes run from DN19 to DN100 and beyond for case drains and tank transfer, with NBR-type tube for oil return and EPDM for coolant and water. Ends are crimped tails, banded nipples or a plain end with a clip, and long runs are coiled so they do not take a set in transit.
We ask two questions on every enquiry: what is the medium and what is the largest bend the route allows. Those answers decide class, bore and cover more reliably than the part number off the old hose, which is usually the one that failed.