Sch 80 is not 80 bar. In ASME B36.10M a schedule fixes a wall per size: Sch 40 on NPS 2 is 3.91 mm, Sch 80 on the same pipe 5.54 mm. At a larger size the same schedule number is a different thickness. EN and ISO practice names a tube by outside diameter with a wall from a dimension series, so the two naming systems do not translate.
Two confusions travel with the schedules. STD, XS and XXS (standard weight, extra strong, double extra strong) come from the older iron-number series and only line up with a schedule over part of the size range, so a substitution is checked size by size rather than from a chart. And DN is a nominal bore, not a measured dimension: DN 50 says nothing reliable about the outside diameter or the wall it arrives with.
Pressure capability is a calculation, not a label. The wall is checked against the allowable stress of the grade at design temperature, with the mill tolerance and a corrosion allowance, under the code the plant is built to - ASME B31.3 or B31.1 on one side, EN 13480 on the other. Mill tolerance belongs in that arithmetic: hot-finished tube standards allow a wall band around plus 15 % and minus 12.5 %, so the calculation must see the minimum.
What each designation names - the two millimetre figures shown are published B36.10M values for NPS 2 (2.375 in, 60.3 mm outside diameter); every other size is a different number| Designation | What it actually is | On NPS 2 / DN 50 | Away from that size | The trap |
|---|
| Sch 40 | a wall series number in ASME B36.10M, not a thickness | 3.91 mm on a 60.3 mm outside diameter | a different wall at every other nominal size | being read as a pressure class by half the market |
|---|
| Sch 80 | the heavier member of the same series | 5.54 mm on the same outside diameter | again size-dependent | the same misreading, plus a smaller bore and more mass |
|---|
| Sch 160 | heavier still, used where the calculation demands it | markedly thicker on the same outside diameter | the series converges toward other names at the large sizes | bend radius, threading and weight all change with it |
|---|
| STD wall | from the iron-number series | coincides with Sch 40 over part of the range | stops coinciding at the larger diameters | assumed identical to Sch 40 across the whole size list |
|---|
| XS and XXS | extra strong and double extra strong | heavier than STD, commonly aligned with Sch 80 at small sizes | only partly aligned at the large sizes | a drawing that says XS and a quotation that says Sch 80 |
|---|
| EN and ISO dimension series (EN 10220, with the product standard governing tolerance) | an outside diameter and wall pair, both written in millimetres | a 60.3 mm tube with, say, a 3.2 mm wall is not the same part as 2 in Sch 40 | nothing scales; both figures are stated | treating an EN series number as a schedule equivalent |
|---|
| DN / NPS nominal designation | a nominal size label, not a measured dimension | DN 50 and NPS 2 describe the same pipe family | says nothing about wall at all | assuming the bore, the outside diameter and the wall follow from it |
|---|
Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.