Xingtai, Hebei · Hebei industrial clusters

Data sheet · VeraBOM & B2B Partner · Engineering Rubber

PVC Waterstop, 300 mm x 3 mm, for Construction Joints

Plan-profile and centre-bulb PVC waterstop for concrete construction and expansion joints, flexible and welded on site with hot-air butt joints, supplied in 20 or 30 m coils.

Reference
pvc-waterstop-300mm-construction-joint
HS code
4016.9990 / 4016.9300 / 7308.9000
Sheet dated
8 September 2026
Issued by
VeraBOM & B2B Partner, Hebei, China

Technical parameters

PVC Waterstop, 300 mm x 3 mm, for Construction Joints — data sheet
ProfilesPlan type, centre bulb, dumbbell, and expansion-joint shapes
Width150 / 200 / 230 / 300 mm; this item 300 mm
Thickness2.5 - 4 mm depending on profile
MaterialModified unplasticised PVC, grey or black
Hardness75 - 85 Sh A with the flexibility stated for cold sites
Coil length20 m or 30 m, cut lengths on request
JointingHot-air butt weld, procedure and test piece supplied
MovementCentre-bulb types accommodate 20 - 50 mm depending on profile
ChemicalResistant to alkaline pore water and normal ground sulphates
StandardProduced to EN 14356-informed geometry principles
AccessoriesCorner pieces, splice patches, wire supports and setting clips

Send your requirement as a marked-up copy of this table and the quotation comes back line by line.

Commercial terms

MOQ
2,000 m per profile and width; 300 m trial coils accepted
Sampling
Sample coil in 5 days; special profile 20 days
Lead time
20-35 days
Packaging
Coils wound and strapped in woven bags with core, protected from sunlight in transit
Shipping
Qingdao; coils stack and travel well in LCL consolidation
If a batch fails
Covered case by case: material defects when stored below UV exposure before installation
Indicative price
Quote only: waterstop prices per metre by profile and width, so we quote per metre for your total length and profile list.
Selling unit
per metre

Engineering features

  • Rib lock geometry that survives imperfect compaction rather than depending on it
  • Cold-site flexibility stated, which is when a waterstop usually gets damaged
  • Weld procedure plus a practice test piece in every shipment
  • Corner and splice accessories in the same profile so no joint is improvised

Materials & grades

  • Modified PVC-U
  • Rubber hydrochloride alternative
  • HDPE profile for aggressive duty
  • Galvanised wire supports

Applications

  • Water tanks, reservoirs and treatment basins
  • Basement slab and wall construction joints
  • Tunnels, culverts and channel linings
  • Dams, docks and marine concrete