Xingtai, Hebei · Hebei industrial clusters

Data sheet · VeraBOM & B2B Partner · Hydraulic Components

Solenoid Directional Control Valve, 4WE6 Pattern, 31.5 MPa, 24 V DC

Screw-in pattern directional valve to the 4WE6 envelope, four spool positions available, 31.5 MPa and 60 L/min, with wet-pin AC/DC solenoids.

Reference
hz-directional-solenoid-valve-we6
HS code
8413.6090 / 8481.2000 / 8412.2900 / 7326.9090
Sheet dated
19 August 2026
Issued by
VeraBOM & B2B Partner, Hebei, China

Technical parameters

Solenoid Directional Control Valve, 4WE6 Pattern, 31.5 MPa, 24 V DC — data sheet
Pattern4WE6 / CETOP 3 screw-in with subplate
Spool symbolsE, A, H, W, J, K, Y and custom underlap
Flow60 L/min standard; 80 L/min with reduced spool force
Pressure31.5 MPa; pilot-operated versions to 35 MPa
ActuationWet-pin solenoid, 12/24 V DC or 110/230 V AC 50/60 Hz
CoilIP65 DIN 43650 form A, LED or rectifier options
PortingG3/8 subplate, NG6 manifold blocks 1 - 20 stations
Inner leakageStated per spool symbol, tested at 25 MPa
Manual overrideSingle or double, captivated or flush
MediaMineral oil, temperature -25 to +80 °C, filtration 20 µm
OptionsAdjustable solenoid detent, pilot chokes, position-indicator vane
Bench testBench pressure, function and leakage test with recorded settings
Export termsEXW / FOB / CIF, Tianjin or Qingdao

Send your requirement as a marked-up copy of this table and the quotation comes back line by line.

Commercial terms

MOQ
MOQ 30 pcs per symbol/voltage; ten pieces per model for pumps and valves, one hundred to five hundred for fittings and accessories.
Sampling
A unit is bench tested and shipped with the flow, pressure and leakage measurements taken on it.
Lead time
10-18 days for common symbols.
Packaging
Ports plugged and capped, flushed and VCI-bagged; boxed per unit with a tag on every port.
Shipping
FOB Tianjin / Qingdao; hose, fitting and valve packages consolidated as one hydraulic kit.
If a batch fails
12 months from B/L date against internal leakage or function failure with correct fluid cleanliness.
Indicative price
Quotation is per unit based on displacement, pressure rating, cavity standard and seal brand.
Selling unit
per piece

Engineering features

  • Spool symbol and detent arrangement written into the order and checked at final assembly
  • Manifold blocks drilled to your circuit map with blind-port plugs fitted
  • Coils from a named brand, replaceable without spool removal
  • Standard and acceptance criteria written into the order: ISO 4401 / CETOP 3 and DIN 43650 form A.
  • Grade substitution is documented, never assumed — Phosphate-treated steel body, Hardened and ground spool, Brass bushing are what we hold to.

Materials & grades

  • Phosphate-treated steel body
  • Hardened and ground spool
  • Brass bushing
  • NBR seals, FKM option

Applications

  • Press and machine tool circuits
  • Clamping and lifting controls
  • Mobile auxiliaries
  • Test benches and manifolds