Xingtai, Hebei · Hebei industrial clusters

Data sheet · VeraBOM & B2B Partner · Pumps & Valves

End-Suction Centrifugal Water Pump, 65-160 to ISO 2858, 7.5 kW

Single-stage end-suction pump on the ISO 2858/EN 733 envelope: 25 m³/h at 32 m, cast iron body, 7.5 kW motor, back-pull-out construction.

Reference
pv-end-suction-water-pump-iso2858
HS code
8413.6090 / 8481.2000 / 8481.8040
Sheet dated
23 August 2026
Issued by
VeraBOM & B2B Partner, Hebei, China

Technical parameters

End-Suction Centrifugal Water Pump, 65-160 to ISO 2858, 7.5 kW — data sheet
StandardISO 2858 / EN 733 dimensional envelope
SizeDN65 discharge, DN80 suction, 160 mm impeller
Duty point25 m³/h at 32 m head
Power7.5 kW IE3, 400 V 3-ph, 2,900 rpm
CasingEN-GJL-200 cast iron, epoxy-coated water passage
ImpellerClosed cast iron or bronze option
SealMechanical seal; gland-packing option for dirty water
Back pull-outYes, without disturbing suction or discharge pipework
BaseplateCommon steel baseplate with machined pads supplied
TemperatureUp to 80 °C clean water standard
TestingHydrostatic casing test and performance check per batch
Bench testBench function, pressure and leak test with record per unit
Export termsEXW / FOB / CIF, Tianjin or Qingdao

Send your requirement as a marked-up copy of this table and the quotation comes back line by line.

Commercial terms

MOQ
MOQ 10 units; ten pieces for catalogue models and one piece for power units, valve blocks and engineered assemblies.
Sampling
Bench run-in with a video record and the measured flow, pressure and oil temperature at your settings.
Lead time
18-28 days.
Packaging
Ports plugged, flange faces guarded, unit crated or on a steel skid; hoses and fittings tagged per connection.
Shipping
FOB Tianjin / Qingdao; circuit packages consolidated as one shipment with a tagged packing list.
If a batch fails
12 months from B/L date, excluding wear parts and seals, subject to correct fluid cleanliness.
Indicative price
Quotation is depends on displacement, pressure class, cavity standard and actuation.
Selling unit
per piece

Engineering features

  • Back pull-out means the seal is changed without breaking pipework
  • Baseplate machined and drilled with the pump, so installation is one job
  • Wear ring clearances stated, which is where efficiency is kept or lost
  • Standard and acceptance criteria written into the order: ISO 2858 / EN 733 and EN GJL-200 material.
  • Grade substitution is documented, never assumed — EN-GJL-200 cast iron, Bronze impeller option, Carbon/ceramic seal are what we hold to.

Materials & grades

  • EN-GJL-200 cast iron
  • Bronze impeller option
  • Carbon/ceramic seal
  • Epoxy coating

Applications

  • Irrigation and drainage
  • HVAC and cooling circuits
  • Industrial water transfer
  • Fire-hydro and booster sets