Horizontal or vertical glass reinforced storage vessel with a resin-selected chemical barrier layer, moulded in sections, with nozzles, level bracing, saddles and a hydrostatic check.
Reference image — production units follow the approved drawing and the specification table below.
A chemical tank is a liner problem before it is a structure problem. We specify the barrier layer from your medium, concentration and temperature — vinyl ester for most aggressive service, iso-polyester for milder duty — and build the structural layers outside it with the wall thickness calculated for the specific gravity you actually store, not for water.
Tanks are moulded horizontally to 5 m and vertically to 3 m diameter, from 500 to 50,000 litres, with the manhole, overflow, drain, vent and level-tapping nozzles positioned from your drawing. Wall thickness is measured ultrasonically at defined points and recorded.
Every tank receives a filled hydrostatic check before dispatch, and the saddle or skirt arrangement is designed for the full weight with the load path stated, so your foundations are built for what arrives.