Data sheet · VeraBOM & B2B Partner · Fiberglass / FRP Products
GRP Lined Chemical Storage Tank, 5,000 Litre
Horizontal or vertical glass reinforced storage vessel with a resin-selected chemical barrier layer, moulded in sections, with nozzles, level bracing, saddles and a hydrostatic check.
- Reference
- grp-chemical-storage-tank-5000l
- HS code
- 6815.1900 / 3926.9097 / 7019.9090
- Sheet dated
- 27 August 2026
- Issued by
- VeraBOM & B2B Partner, Hebei, China
Technical parameters
| Volume | 500 - 50,000 litres; this item 5,000 litres |
|---|---|
| Orientation | Horizontal on saddles or vertical on a skirt |
| Barrier layer | Vinyl ester or iso-polyester, chosen from your medium |
| Structure | Calculated for the stored specific gravity up to 1.6 |
| Wall thickness | 6 - 30 mm by diameter, ultrasonically measured and recorded |
| Nozzles | Manhole DN500, drain, overflow, vent, level and sample tappings |
| Testing | Hydrostatic fill check before dispatch, record supplied |
| Support | Saddles or skirt with load path and foundation notes |
| Lining option | PTFE or plate lining for extreme duty |
| Temperature | Typical to +90 °C; higher on vinyl ester with the correct cure |
| Standard basis | Designed to ASTM D3299 / BS 4994-informed practice |
| Delivery | Moulded complete or sectioned for out-of-gauge sites |
Send your requirement as a marked-up copy of this table and the quotation comes back line by line.
Commercial terms
- MOQ
- One vessel; multi-tank orders scheduled to your installation sequence
- Sampling
- Design submittal in 10 days; a prototype vessel 45-60 days
- Lead time
- 45-70 days from approved nozzle drawing
- Packaging
- Vessel on a timber cradle with nozzle protection, wrapped against UV for storage
- Shipping
- Breakbulk or flat-rack for large vessels; sectioned tanks travel in containers
- If a batch fails
- Covered case by case: laminate and liner defects under the stated medium and temperature
- Indicative price
- Quote only: tanks are project-priced by volume, medium and nozzle set, so we quote from your chemical data, layout and quantity.
- Selling unit
- per piece
Engineering features
- Barrier layer chosen from your chemical data, with the reasoning in the submittal
- Wall thickness measured and recorded, not assumed from the moulding log
- Hydrostatic check before despatch on every tank
- Sectioned construction available when the site cannot accept a complete vessel
Materials & grades
- Vinyl ester resin
- Isophthalic polyester
- E-glass mat and roving
- PTFE lining option
- Steel support frame
Applications
- Acid, alkali and plating-bath storage
- Effluent and neutralisation tanks
- Water treatment and brine service
- Chemical dosing and process buffer vessels