Xingtai, Hebei · Hebei industrial clusters

Pumps & Valves · Cangzhou hydraulic cluster / Shijiazhuang valve trade

Accumulator-Charged Hydraulic Unit for Test Rigs, Pulsation-Damped

Low-pulsation hydraulic supply with 10 L accumulator bank, servo-compatible filtration and cooling, sized for fatigue rigs and sustained load holding.

Accumulator-Charged Hydraulic Unit for Test Rigs, Pulsation-Damped manufactured in Hebei, China by VeraBOM & B2B Partner

Reference image — production units follow the approved drawing and the specification table below.

Built for mobile-hydraulics builders and process-plant buyers. Low-pulsation hydraulic supply with 10 L accumulator bank, servo-compatible filtration and cooling, sized for fatigue rigs and sustained load holding. A rig pump must hold pressure without heat and without ripple, so accumulator sizing, filtration and cooling carry the specification. The two lines that decide the application are application (Fatigue, proof and hold testing with load or pressure control) and accumulation.

What we hold fixed on this item is the application: Fatigue, proof and hold testing with load or pressure control. Around it sit supply (15 L/min at 21 MPa from a 4 kW unit), accumulation (3 × 10 L bladder accumulators, pre-charge set to circuit), and pulsation (Under 1.5 bar ripple at the test port with accumulators connected). Built and inspected to ISO 4413 and EN 14359 accumulator practice. Used in component fatigue and proof testing, seal and hose test benches, cylinder run-in stations, laboratory and university rigs, that combination is where the accumulator-charged hydraulic unit for test rigs earns its price.

Verification documents are compiled against the order: shell and seat tests per API 598 or EN 12266 for valves, function and leakage records for hydraulic components. Packing follows the same logic — ports plugged and flanges guarded, units crated or skidded with hose sets and fittings tagged together — and FOB Tianjin / Qingdao; circuit packages consolidated as one shipment with a tagged packing list. Quotation depends on displacement, pressure class, cavity standard and actuation.

Specification

Technical parameters — the table we quote against

Send your requirement as a marked-up copy of this table and the quotation comes back line by line.

Accumulator-Charged Hydraulic Unit for Test Rigs, Pulsation-Damped — data sheet
ApplicationFatigue, proof and hold testing with load or pressure control
Supply15 L/min at 21 MPa from a 4 kW unit
Accumulation3 × 10 L bladder accumulators, pre-charge set to circuit
PulsationUnder 1.5 bar ripple at the test port with accumulators connected
Filtration6 µm absolute with online particle counter port
TemperatureWater-cooled with 3 °C control band
ControlLoad-sensing with proportional pressure control option
InstrumentationDigital pressure and temperature display, data logging port
SafetyAccumulator safety block, dump valve and pressure relief
MountingBench skid with forklift pockets and cable entry
TestingRipple and hold test recorded per unit before despatch
Bench testBench function, pressure and leak test with record per unit
Export termsEXW / FOB / CIF, Tianjin or Qingdao

Engineering features

  • Accumulator volume and pre-charge calculated for your hold time and temperature band
  • Ripple measured at the test port and reported, not estimated
  • Ports and logging connections left accessible for your instrumentation
  • Standard and acceptance criteria written into the order: ISO 4413 and EN 14359 accumulator practice.
  • Grade substitution is documented, never assumed — Bladder accumulators, Stainless tubing, Anodised manifold are what we hold to.

Materials & grades

  • Bladder accumulators
  • Stainless tubing
  • Anodised manifold
  • Powder-coated skid

Applications

  • Component fatigue and proof testing
  • Seal and hose test benches
  • Cylinder run-in stations
  • Laboratory and university rigs

Accumulator-Charged Hydraulic Unit for Test Rigs, Pulsation-Damped: questions before you order

What is the MOQ for the accumulator-charged hydraulic unit for test rigs?

The accumulator-charged hydraulic unit for test rigs ships from 1 unit per specification. Less is possible when the size is a stocked one, because ten pieces for catalogue models and one piece for power units, valve blocks and engineered assemblies.

Can we sample the accumulator-charged hydraulic unit for test rigs before the batch?

Yes. Bench run-in with a video record and the measured flow, pressure and oil temperature at your settings. For the accumulator-charged hydraulic unit for test rigs the report records application (Fatigue, proof and hold testing with load or pressure control) and supply (15 L/min at 21 MPa from a 4 kW unit), so approval is against measured data and not a photograph.

How long does the accumulator-charged hydraulic unit for test rigs take to produce and ship?

35-50 days after approval of the drawing or sample and receipt of deposit. Standard models take two to four weeks; engineered power units are built to the circuit and take five to seven. The date is confirmed on the order acknowledgement, and a slip is flagged the week it happens rather than the week of sailing.

Which certificates and test reports come with the accumulator-charged hydraulic unit for test rigs?

Shell and seat tests per API 598 or EN 12266 for valves, function and leakage records for hydraulic components. Where a project needs a named third party — SGS, BV, witnessed testing or mill certificates to EN 10204 3.1 — that is arranged at order stage, because it changes the schedule and not only the invoice.

How is the accumulator-charged hydraulic unit for test rigs packed for export?

Ports plugged and flanges guarded, units crated or skidded with hose sets and fittings tagged together. FOB Tianjin / Qingdao; circuit packages consolidated as one shipment with a tagged packing list. Weights, carton or crate dimensions and the loading plan are on the packing list in advance, so unloading is planned rather than improvised.

Related categories in this shipment

Buyers of this item usually consolidate these as well — one container, one document pack, one inspection file.

Need a modification to this part?

More from this category

Other pumps & valves specifications

Comparing this part with another? The RFQ spec template puts both on one page, and the pre-shipment checklist is what we inspect against before the balance is paid.

Ask about this part — quantity, destination port, deviations

Request for quotation

Tell us what you need made or sourced

Send drawings, a photo or just a part name — we reply within 1 working day.

Only your name, your e-mail and the requirement — typed or recorded — are needed to send. Leave anything else blank and it comes back as a question in our reply instead of stopping you here.

Name, company and e-mail are the only required fields — nothing else blocks the enquiry.

Drawings are treated as confidential — tell us if you need an NDA first, and we will send one before you attach anything.

PDF, DWG, DXF, STEP, IGES, SLT, Office, CSV, PNG, JPG, ZIP or an audio recording — up to 4 files, 10 MB each.

We log the file list with your enquiry; the files themselves travel to the sales desk as mail attachments, not into a database record. Bigger than this? Send quote@verabom.com a link and we will pick it up.

By sending this form you agree we may contact you about this enquiry. We never resell your data — see our privacy policy.

Written first reply within 1 working day; priced answer within 2-5 working days.

Request a quotation for this part

Tell us quantity, destination port and any deviation from the data sheet above. We reply with a priced, dated quotation, the production route and the inspection plan.