The class number is a strength statement: the first digit times 100 is the minimum tensile strength in MPa, and the second digit times the first times 10 is the minimum yield. So 8.8 means 800 MPa tensile with 640 MPa yield, 10.9 means 1040 and 940, and 12.9 means 1220 and 1100 MPa, all to ISO 898-1 for metric bolts in the sizes its tables cover.
The head is a separate choice. ISO 4017 is the hexagon head bolt with full thread; ISO 4014 is the same head with an unthreaded shank. The shank matters where the bolt is in shear or where threads sitting in the fatigue plane would start a crack: plain shank in the shear plane, threads only in the clamped length. Same wrench size, same class, different load path.
Class alone does not protect you. Higher classes are more sensitive to hydrogen embrittlement and notch effect, so an electro-plated 12.9 bolt in a wet environment can fail weeks later with no warning. Where you need corrosion resistance with moderate strength, austenitic A2-70 or A4-80 to ISO 3506 is often the honest answer.
Property classes and their minimum mechanical values| Class or designation | Min. tensile Rm | Min. yield Rp0.2 | Hardness picture | Normal use |
|---|
| 8.8 (ISO 898-1) | 800 MPa | 640 MPa | about 250-350 HV, band depends on size | Machine bolts, general assembly, secondary steelwork |
|---|
| 10.9 (ISO 898-1) | 1040 MPa | 940 MPa | about 320-390 HV | Wheel bolts, chassis, high-strength bolted joints |
|---|
| 12.9 (ISO 898-1) | 1220 MPa | 1100 MPa | about 390-440 HV | Small highly loaded screws, tooling, bolted dies |
|---|
| A2-70 (ISO 3506) | 700 MPa | 450 MPa | work-hardened austenitic | Outdoor, food and marine-adjacent duty |
|---|
| A4-80 (ISO 3506) | 800 MPa | 600 MPa | work-hardened austenitic | Coastal and chemical exposure |
|---|
| 5.6 / 6.8 (low carbon) | 500 / 600 MPa | 300 / 480 MPa | soft, free-machining | Light brackets, non-critical fixings |
|---|
Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.