A structural high-strength bolt is sold as a system, not as a screw. EN 14399 supplies bolt, nut and washers as one set with a declared friction coefficient and a required pretension, and the joint is designed to carry load by friction between the faying surfaces. An ordinary class 10.9 bolt tightened to a torque value is a fastener, not a bolting system.
The two main families are HV, a large hexagon head used with hardened washers, and HR, a countersunk head used where the surface must stay flush. Designations such as HV6, HV10, HR6 and HR10 differ in head form, size range and tightening-control method, and the pretension values are tabulated by diameter in the relevant part of the standard.
The wedge load test is how the head and thread are proved rather than the shank. The bolt is pulled with a hardened wedge under its head; the fracture must occur in the shank or with at least one engaged thread past the nut face. A head or fillet failure means the fillet radius, the forging or the heat treatment has a problem, whichever class was ordered.
What each test and requirement actually proves| Test or requirement | What it proves | Governing document | How we verify at receipt |
|---|
| Wedge tensile (wedge load) test | Head, fillet and thread in the real load path | ISO 898-1 for property classes | Certificate plus a sampled pull test on the lot |
|---|
| Hardened wedge under the head | Forces failure away from the anvil so a weak fillet cannot be masked | ISO 898-1 test method | Photograph of the rig and the fracture in the report |
|---|
| Tensile Rm and yield Rp0.2 | The material class of the bolt itself | ISO 898-1, EN 14399 | Head markings cross-checked against the certificate |
|---|
| Rotational capacity test | The nut and washer do not seize before the bolt yields | EN 14399 parts for the system ordered | Requested and recorded on preloaded orders |
|---|
| Pretension and control method | The friction grip actually forms in the joint | EN 14399 with the design rules of EN 1993-1-8 | Tightening instruction in the shipment file |
|---|
| Declared slip factor | The faying surface condition you may design for | EN 1993-1-8, verified on site | Blast profile and test report on file |
|---|
Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.