Cover grade and joint method are one decision, not two. The cover takes the impact and the abrasion; the splice carries the tension, and a splice can only keep the share of belt strength its method allows. A hot vulcanised joint approaches full carcass strength, a cold adhesive joint keeps a smaller share, and a mechanical fastener typically keeps well under half.
Belts are designated by carcass and strength, in the common form EP 400/4 10+3: EP for the polyester fabric carcass, 400 for tensile strength in newtons per millimetre of width, 4 for the number of plies, and 10 and 3 mm for the top and underside cover thickness. Steel cord belts are designated by cord strength and are spliced by vulcanising to the maker tables only.
Cover rubber is chosen by what it carries: abrasion, load temperature, oil or fat in the stream, and whether the site demands fire resistance. Those are compound decisions with test methods behind them - the standard abrasion volume-loss test, immersion volume change to ISO 1817, and the fire and surface-resistance tests that underground duty requires. Material and belt dimensions sit in EN ISO 14890.
Splice methods and the belt strength each one keeps| Splice method | Share of tensile strength kept | What it needs on site | Where it is the wrong answer |
|---|
| Hot vulcanised (press) | approaches the full carcass strength when correctly made | skived step joint, press at the stated temperature, pressure and time, controlled cooling | short shutdown windows, and steel cord joints made without the maker tables |
|---|
| Cold vulcanised (room-temperature adhesive) | a substantial but lower share, wholly dependent on surface preparation | buffed rubber and fabric, primer, full clamp pressure across the overlap, minimum cure temperature | hot, wet or oil-washed joints and long high-tension conveyors |
|---|
| Hinged mechanical fasteners | typically well under half | belt thickness inside the fastener range and the correct punch pitch | steep inclines, high tension, transfer points and pulley nips |
|---|
| Bolted clamp lacing | the lowest share, and a permanent wear point | a clean cut edge and regular re-tensioning | continuous-duty plants and any long route |
|---|
| Steel cord splice | full strength only as a vulcanised stepped splice | the maker splice table, cord spacing and cover build-up | never with mechanical fasteners |
|---|
Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.