No. Q355B (GB/T 1591) and S355J2 (EN 10025-2) both guarantee 355 MPa minimum yield at 16 mm thickness, but Q355B is Charpy-impact tested only at +20 °C while S355J2 is tested at −20 °C. A36 (ASTM A36) guarantees 250 MPa yield, and SS400 (JIS G3101) is a tensile-based grade with no impact requirement, so neither is a like-for-like substitute in a loaded welded frame.
The substitution usually arrives as a price question: a mill offers A36 plate because it is on hand, cheaper and called equivalent. It is not. A member designed with a 355 MPa allowance loses roughly 30 % of its yield margin at 250 MPa, so the beam either deflects more or must be upsized - and the upsize changes connection details you already froze.
Impact testing is where the difference bites. EN grades carry a letter for the test temperature (J0 at 0 °C, J2 at −20 °C, K4 at −40 °C) and GB grades use the same logic (Q355B at +20 °C, C at 0 °C, D at −20 °C, E at −40 °C). For a cold site or a dynamically loaded member, the letter decides, not the number 355.
Structural steel grades - minimum values from the named standard, flat product up to 16 mm thickness| Grade | Standard | Min. yield Rp0.2 at 16 mm | Tensile Rm | Charpy V-notch requirement |
|---|
| Q355B | GB/T 1591 | ≥355 MPa | 450–630 MPa band, tabulated by thickness; certified value governs | 27 J minimum at +20 °C |
|---|
| Q355D | GB/T 1591 | ≥355 MPa | 450–630 MPa band, tabulated by thickness | 27 J minimum at −20 °C |
|---|
| S355J2 | EN 10025-2 | ≥355 MPa | 450–600 MPa for 3–100 mm | 27 J minimum at −20 °C, longitudinal |
|---|
| S355J0 | EN 10025-2 | ≥355 MPa | 450–600 MPa for 3–100 mm | 27 J minimum at 0 °C, longitudinal |
|---|
| A36 | ASTM A36/A36M | ≥250 MPa up to 100 mm thickness | 400–550 MPa | Not specified by the grade |
|---|
| SS400 | JIS G3101 | not a yield-based grade; JIS gives an upper yield point by thickness band, about 245 MPa at 16 mm or thinner | 400–510 MPa above 16 mm | Not specified by the grade |
|---|
Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.