None of them automatically. In EN 10213 the family and chemistry make an answer possible; the Charpy V-notch test temperature is a condition you write into the order. A valve body or pump casing specified only as cast steel can arrive with toughness proven at +20 °C and then behave in a winter commissioning test exactly like the specification did not require.
Read the designation as three decisions. The non-alloy and lightly alloyed weldable cast steels - the general-pressure family, where a figure such as 240 names a minimum yield for a stated thickness band - are the ordinary ambient answer. The low-alloy chromium-molybdenum grades, quenched and tempered, buy strength and elevated-temperature behaviour. The austenitic and duplex cast stainless families keep working where a ferritic steel cannot be qualified, because face-centred-cubic iron has no ductile-to-brittle transition to fall off.
What must be contracted is the test: temperature, energy, and whether acceptance is an average or an individual value. Heat treatment belongs in the same order, because a toughness claim about a casting that was not heat-treated as the grade requires is a claim about a coupon, not about your part. Section is the last constraint - a 90 mm boss cannot be through-hardened like a 20 mm wall, which is why the standard tabulates by thickness band.
EN 10213 families and how low-temperature capability is actually contracted; strength and impact values are tabulated by thickness band and heat treatment - confirm the band for your wall on the certificate| Family and example designation | Metallurgy | What the standard asks for | Low-temperature picture | Typical part |
|---|
| CS general-pressure non-alloy weldable cast steel (GP 240 GH type) | carbon cast steel, weldable with a qualified procedure | yield and tensile minima by thickness band, plus impact at the temperature stated in the order | the ordinary default is tested at +20 °C; anything lower is an added condition, not implied | pump and valve bodies, pressure housings, gear cases at ambient |
|---|
| CS slightly alloyed weldable (G 235 Cr type) | non-alloy to low-alloy, normalised condition | tensile band and hardness limits by section | same logic: the test temperature is written by the buyer | housings and frames where welding and machining lead |
|---|
| LS low-alloy specified-property grades (G 20 Cr Mo 5 type) | about 1 % Cr - 0.5 % Mo, normally quenched and tempered | a hardness or tensile window for the condition, with impact at the contracted temperature | capable of sub-zero testing when the heat treatment and the test are ordered together | loaded hubs, high-pressure bodies, gear and pinion blanks |
|---|
| LT orders with defined low-temperature toughness | nickel-alloyed or carefully heat-treated ferritic grades | Charpy V-notch energy at 0, -20, -40 or -60 °C as specified | this is the family you name when the design temperature is below freezing | refrigeration, cold-region and LNG-adjacent pressure parts |
|---|
| Austenitic cast stainless - 1.4308 and 1.4408 types | Cr-Ni and Cr-Ni-Mo, face-centred cubic | their own strength band, with impact usually agreed rather than transition-limited | the practical answer well below what ferritic cast steel can be qualified for, down to cryogenic service | seawater, chemical and cryogenic housings and valve bodies |
|---|
| Ferritic-austenitic (duplex) cast - 1.4462-type chemistry | duplex Cr-Ni-Mo-N | a higher strength band than the austenitic grades with agreed impact values | tough at moderately low temperature and strong against chloride, within the process standard temperature limits | pressure parts in chloride and seawater duty |
|---|
Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.