Xingtai, Hebei · Hebei industrial clusters

Specification reference · updated 29 September 2026

Is an EN 853 1SN hose the same as a SAE 100 R1AT hose, and which one carries my pressure?

Mostly, but the cover differs. EN 853 1SN and SAE 100 R1AT are both single-braid wire hoses, EN 854 2SN and R2AT both two-braid, and the AT suffix marks the thin cover made for crimped fittings. Working pressure comes from the table for the bore in the standard you buy to - it does not transfer between families; a crimp die set matched to one cover thickness blisters the other.

Mostly, but the cover differs. EN 853 1SN and SAE 100 R1AT are both single-braid wire hoses, EN 854 2SN and R2AT both two-braid, and the AT suffix marks the thin cover made for crimped fittings. Working pressure comes from the table for the bore in the standard you buy to - it does not transfer between families; a crimp die set matched to one cover thickness blisters the other.

Reinforcement geometry is the other axis. Braid flexes, so it is the default on circuits that move; EN 856 spiral and helix types (4SP, 4SH) lay four wire plies for pressure and impulse and are not meant to bend repeatedly. Both families are qualified by impulse cycling rather than one static burst, and the customary burst margin of about four times working pressure is a design rule, not a running allowance.

The last decision belongs to the assembly, not the hose. Coupling dimensions for braid hose are in EN ISO 6802, spiral assemblies for mobile equipment in ISO 18752, the impulse test method is EN ISO 6803, and ISO 1436 covers the general design and test principles for wire-reinforced assemblies. Buy the hose to a named standard, build the assembly to a documented crimp procedure, and keep both records together.

Wire-reinforced hose families - construction and where the pressure figure legitimately comes from
DesignationReinforcementCover and fitting routeWhere the working pressure comes fromWhere it belongs
EN 853 1SNOne braid of high-tensile steel wireStandard cover; no-skive or cut-skive ferrulesThe EN 853 table for the bore and series you orderedPressure and return lines in machine hydraulics at moderate working pressure
SAE 100 R1ATOne braidThin cover, sized for no-skive crimpingThe SAE J517 R1AT table for the sizeSame role as 1SN; the cover thickness and the die set are the difference
EN 854 2SNTwo braidsCut-skive or full-ferrule crimp matched to the coverThe EN 854 table for the boreHigher working pressure and impulse duty than 1SN in the same bore
SAE 100 R2ATTwo braidsThin cover, no-skive crimpThe SAE J517 R2AT tableThe everyday mobile-equipment two-braid hose
SAE 100 R12 / R13High-pressure wire construction; ply count read from the J517 table for the sizeThin cover, skived or no-skive per the fitting instructionThe SAE J517 tables for R12 and R13Circuits above what a two-braid hose carries in that bore
EN 856 4SPFour spiral pliesSkive with a heavy ferrule, crimp to the maker procedureThe EN 856 table for type 4SPHigh pressure in a line that stays reasonably straight
EN 856 4SHFour helix pliesSkive and crimp to the maker procedureThe EN 856 table for type 4SHLarge-bore very-high-pressure duty; the least flexible of the group

Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.

Where this costs money

Three situations where the difference becomes a claim

Each is a decision taken at quotation stage, while the specification is still cheap to change.

A 1SN hose crimped with dies set for a thin-cover hose

The ferrule collapses the cover it was designed around. On a thicker cover the same crimp diameter over-compresses the tube and blisters the rubber at the ferrule edge, and the assembly passes a visual check then blows the fitting off the first hot impulse. Crimp diameter comes from the fitting maker table for the specific hose standard and cover - it is recorded per assembly, not remembered.

A cross-reference chart replaces the test record

Equivalent hoses on a chart are not equivalent assemblies. What proves a hose is the impulse result at the multiple of working pressure and the cycle count in the standard it was qualified to, plus the assembly proof. A supplier document that names only a static burst number has not proved impulse life, and we ask for the impulse record before the first order.

Spiral hose bent around a tight radius

Spiral plies are laid for pressure, not for flexion; bending them repeatedly at a small radius opens the wire ends at the skive and the assembly fails at the ferrule rather than mid-hose. Where the line moves, the answer is normally a braid type in the next construction class up, at the minimum bend radius published for that bore.

Questions buyers ask before they commit the specification

Which is stronger, EN 854 2SN or SAE 100 R2AT?

They are the same construction class: two wire braids. The practical difference is the cover - R2AT is built with a thin cover for no-skive crimped fittings - and the working pressure you are entitled to use is the figure in the table for the bore in the standard you bought to. Compare bore and pressure directly; do not assume the names rank.

Can I fit a hose rated far above my circuit pressure?

Sometimes it is the right answer, but check what else changes. Heavier construction costs flexibility, raises the minimum bend radius and needs a different ferrule and crimp, and the coupling must be rated for the hose as well. A circuit that needs 16 MPa does not benefit from a 40 MPa spiral hose if it now kinks where the old line flexed.

What should be marked on a finished assembly?

The hose standard and type, the bore, the batch or date code, and the identity of the assembly maker, in line with the marking requirements of the applicable hose standard and ISO 1436. Ask additionally for the crimp diameter record, the coupling batch and a proof-test certificate for the size, and keep them with the delivery note - that is the packet an insurer or a customer audit asks for.

How does temperature affect the rating?

A general-purpose wire-braid hose with a nitrile tube is commonly used from about -40 °C to +100 °C in oil, and the standard for the type publishes the band and any derating. Sustained heat above that hardens the tube and the cover and cracks them at the ferrule; hot water, steam and glycol need a different compound, and the coupling seals age at the same rate as the hose.

Do you supply the hose or the assembly?

Both routes. We buy hose to the named standard and size, place the assembly with crimp shops that work to the fitting maker tables, and require the crimp record and proof test with the goods. We are the purchasing and inspection desk, not a hose maker, so the documents we hand you carry the maker standard and the measurements we took.

Fit this to a real part

Send the drawing and the answer comes back with your numbers

The quotation for hydraulic hose assemblies repeats this comparison against your grade, dimension, tolerance and test package, and names any deviation before production starts.

Ask about this specificationHydraulic Hose Assemblies category hub

How we verify it

  • Grade and condition checked against the EN 10204 3.1 certificate and the heat marking.
  • Boundary dimensions, class, clearance or rating measured on the inspection sheet.
  • Deviations offered in writing before production, never discovered after shipment.

Trading and sourcing company based in northern Xingtai, Hebei, about 60 km south of the provincial capital. We buy across the industrial clusters of central and southern Hebei and reach the northern ones on scheduled factory runs; the supplier visits, benchmarking and pre-shipment inspection are ours, done in person. Not a factory. Multi-category, quoted from drawings, consolidated into one container and one document pack, and inspected before the balance is paid; every order starts as an RFQ.

Inspection and documents →

Written first reply within 1 working day; priced answer within 2-5 working days.

Quote it against your part, not the chart

Send the drawing, the standard your engineer named and the quantity. We reply with the priced specification, the substitution we recommend and why, and the inspection plan that proves it.