Is an HE 200 B the same as a W8x35, and can an IPE replace a wide-flange beam?

No, and the naming misleads. EN 10365 names European sections by family and size: HE 200 B is a wide-flange H-section about 200 mm deep in the B thickness series. An American W-shape is named by nominal depth in inches and mass in pounds per foot, so W8x35 is roughly 203 mm deep and 52 kg per metre. Two numbers that look interchangeable describe different webs, flanges and root radii.

No, and the naming misleads. EN 10365 names European sections by family and size: HE 200 B is a wide-flange H-section about 200 mm deep in the B thickness series. An American W-shape is named by nominal depth in inches and mass in pounds per foot, so W8x35 is roughly 203 mm deep and 52 kg per metre. Two numbers that look interchangeable describe different webs, flanges and root radii.

Each family answers a different question. HE sections put the flange width close to the depth with parallel faces, and the letter in the designation runs upward in web and flange thickness. IPE is a parallel-flange beam with a narrow flange - IPE 300 is 300 mm deep against a 150 mm flange - efficient in one axis, weak in the other. UPN and the older IPN have inclined inner flange faces, a connection detail before a strength one.

American shapes are a different taxonomy. W is nominal depth in inches with pounds per foot, S shapes have inclined inner flange faces, and C and MC channels slope on the inner face, so a flat bearing surface does not always exist. A substitution is therefore a property comparison - area, section modulus about both axes, radius of gyration and torsional constant - against EN 10034 or ASTM A6 tolerances and the relevant grade standard.

What each designation says and what it leaves unsaid - section properties and dimensional tolerances come from the standard tables and the mill document, not from this row
DesignationWhat the name statesGeometry factIts neighbour in the other systemWhere the substitution bites
HE 200 A / B / M (EN 10365)an H-section about 200 mm deep, in the A, B or M thickness seriesflange width nominally equal to depth, parallel facesW8-series shapes in spirit, none of them identicalA, B and M share an envelope with different thickness, so a connection designed for B may be wrong on A
IPE 300a parallel-flange beam 300 mm deepnarrow 150 mm flange, parallel facesno W-shape with the same proportionsminor-axis buckling and local flange loading; it will not carry the same bolt group or the same bearing
UPN / IPNEuropean I-beams with inclined inner flange facesno flat inner bearing surface exists on the flangeAmerican S shapes share the problemgussets, end plates and copes need packing plates or a milled face, and copied details loosen or leak load path
W8x35nominal depth 8 in (about 203 mm) and 35 lb/ft (about 52 kg/m)flange width varies between sizes of the same nominal depthHE 200 B in mass, not in detailtwo W8 shapes differ in flange width, so minor-axis behaviour and the connection both change
S12x35 (American standard beam)nominal depth in inches with pounds per footinner flange faces inclined, so bolted connections need sloped washers or a milled faceUPN and IPN in purposea connection copied from a W-shape detail will not sit flat on the flange
C10x20 and MC channelsnominal depth in inches plus mass per footAmerican channels have a sloped inner flange face, so the bearing face is not parallelEuropean and parallel-flange channels differ in proportion and radiusstiff bearing, bolted end connections and flush plate details all need coping or packing
Angles and teeslegs or flange and web named by size and thicknessa tee cut from a beam inherits the parent section propertiesequivalent L and MT shapes on the American listan angle used as a beam twists; the weak axis and the connection eccentricity govern

Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.

Where this costs money

Three situations where the difference becomes a claim

Each is a decision taken at quotation stage, while the specification is still cheap to change.

A W-shape bought as the HEA the drawing called for

The depth matches, so nobody looks further - and then the flange is narrower and thinner than the connection was designed around, which changes the bolt group, the local bending at the flange and sometimes the bearing length. We put the two property tables side by side on the quotation and mark every difference, so the engineer approves a substitution rather than discovering it on the frame.

Tapered flanges meet a flat end plate

On IPN, UPN and the American S and C series the inner flange face is inclined, so a gusset or end plate contacts on an edge and the joint rotates. The remedy is a tapered packing plate, a coped member or a milled face, agreed and drawn - not a washer stack assembled by whoever is on the bench that day.

Mass per metre used as a strength argument

Kilograms per metre and pounds per foot are different units describing the same idea, and 35 lb/ft is about 52 kg/m. Where a section is chosen by weight alone the substitution can be stronger or weaker in the axis that matters, so the comparison is made on section modulus and radius of gyration, with the mass shown as a check on the freight bill.

Questions buyers ask before they commit the specification

Which HE series is the heaviest for the same size?

The letter series runs upward in web and flange thickness within the same nominal envelope, so A is the lightest and M the heaviest of the common European H-series, with the intermediate letters between them. Depth and width shift slightly between the series, which is why the actual dimensions are read from the table for the designation rather than inferred from the number in the name.

Can an IPE replace a W-shape of the same depth?

Sometimes for bending about the strong axis, and often not for the details. An IPE has a narrow flange, so lateral-torsional buckling, local wheel or bearing loads, bolted connections and any moment about the weak axis behave differently. Replace it by calculation with the section tables open, and record the check - the depth being equal is not the design being satisfied.

Do the two systems use the same tolerances?

No. European hot-rolled open sections are dimensioned and toleranced through EN 10365 with the shape and dimension tolerances of EN 10034, while American shapes are delivered to ASTM A6 tolerances for the relevant rolling group. Depth, camber, sweep, flange width and web thickness each have their own bands, and the web tolerance matters because it feeds the shear check.

What should the order say to avoid the trap?

The designation, the standard the section is rolled to, the grade with its delivery document type, and the dimensions or properties that have to be achieved - for example "HE 200 B to EN 10034 tolerances, S355J2+N to EN 10025-2, EN 10204 3.1". If an equivalent is acceptable, say what it must not compromise, and ask for the substitute property table back with the price.

Do you buy both systems?

We buy European sections from mills rolling to EN designations and grades and American shapes to ASTM, and the quotation attaches the dimension and property table for the section actually being supplied. Where a substitution is proposed we show both columns with the differences marked - which is the part that stops a frame arriving with connections that do not close.

Fit this to a real part

Send the drawing and the answer comes back with your numbers

The quotation for steel products repeats this comparison against your grade, dimension, tolerance and test package, and names any deviation before production starts.

Ask about this specificationSteel Products category hub

How we verify it

  • Grade and condition checked against the EN 10204 3.1 certificate and the heat marking.
  • Boundary dimensions, class, clearance or rating measured on the inspection sheet.
  • Deviations offered in writing before production, never discovered after shipment.

Trading and sourcing company based in northern Xingtai, Hebei, about 60 km south of the provincial capital. We buy across the industrial clusters of central and southern Hebei and reach the northern ones on scheduled factory runs; the supplier visits, benchmarking and pre-shipment inspection are ours, done in person. Not a factory. Multi-category, quoted from drawings, consolidated into one container and one document pack, and inspected before the balance is paid; every order starts as an RFQ.

Inspection and documents →

Written first reply within 1 working day; priced answer within 2-5 working days.

Quote it against your part, not the chart