Xingtai, Hebei · Hebei industrial clusters

Specification reference · updated 29 September 2026

Which hydraulic cylinder mounting style do I need, and what do the mounting codes actually change?

The mounting decides three things before the bore does: where the reaction load enters the machine, how much side load the rod sees, and how much misalignment the joint absorbs. Foot and flange mountings - the metric families of ISO 6020-1 and ISO 6020-2 - are rigid and demand alignment. Eye, clevis and trunnion mountings pivot, so they self-align but load a pin that must be sized for it.

The mounting decides three things before the bore does: where the reaction load enters the machine, how much side load the rod sees, and how much misalignment the joint absorbs. Foot and flange mountings - the metric families of ISO 6020-1 and ISO 6020-2 - are rigid and demand alignment. Eye, clevis and trunnion mountings pivot, so they self-align but load a pin that must be sized for it.

Bores are not free choices either. The metric line-mounting family runs on the ISO 3302-1 bore series - 40, 50, 63, 80, 100, 125, 140, 160, 180, 200 mm - with rod diameters from the ISO 3302-2 preferred-number series. Move to the neighbouring bore and the tube, gland, port position and mounting all change, so a substitution is never cosmetic.

The mistake we see most often is a rigid mounting bolted to a bracket that flexes: the cylinder binds, the gland wears on one side, and the seal kit dies inside a season. Send the mounting face and the mating structure drawing, and the quotation flags the alignment and pin-sizing consequences instead of discovering them on the machine.

Mounting families and what each one does with the load
Mounting familyHow the load reactsAlignment demandSide load on the rodUsual duty
Foot or block mountingBending in the mounting bolts, shear into the baseFaces must be coplanar and parallel within the machine tolerancePoor - rigidPresses, shears, fixed stations
Square flange, head endDirect compression into the machine faceBolts and face must run truePoor - rigidClamping and feeding with an axial load path
Circular line flange, cap endCompression into a round bossPilot or dowel location recommendedPoor - rigidMachine tool and mill-type service
Single eye with spherical bushThrough the pin, in bearingAbsorbs a few degrees of angular errorAcceptable if the bush is sizedLoader links, tipping gear, pivoting frames
Clevis or tangTwo shear planes in the pinAllows oscillationAcceptableRod-end attachment on moving structures
Trunnion or pivot pinCentral pivot, tension into the tie rodsModerateAcceptableLong-stroke oscillating applications

Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.

Where this costs money

Three situations where the difference becomes a claim

Each is a decision taken at quotation stage, while the specification is still cheap to change.

You copied the mounting code from an inch-series catalogue

The ISO metric letter set and the North American inch-series letter set are not the same codes, and a letter that looks identical can put the flange at the opposite end or the feet on the wrong face. Confirm the mounting by dimensioned sketch - which end, which face, bolt pattern and port position - never by the letter alone.

Port thread and port position move with the mounting

ISO 6149 metric ports sealed with an O-ring face, BSP ports sealed with a bonded washer, and bolted flange ports are not interchangeable without re-tapping the block. The port location also decides hose bend radius and whether the fitting clears the machine, so it belongs in the same decision as the mounting.

Stroke and buckling set how strong the mounting must be

A long, slender rod in compression is a column, and the effective column length depends on how both ends are held. A pivoting mounting changes the buckling calculation from a rigid flange mounting, so send stroke, mounting and working load together and we run the check before quoting the rod diameter.

Questions buyers ask before they commit the specification

What is the difference between ISO 6020-1 and ISO 6020-2?

Both specify line mountings and ports for metric cylinders, and between them they cover the tie-rod and clamp family and the larger bolted bores. In practice the two parts split the pressure band and size range, so quote the part and the edition on your drawing rather than the bare number - the mounting faces and port details differ between them.

Can you work from a photo of the old cylinder?

Yes, with the mounting centres, bore, stroke, rod diameter and port threads. We produce a reverse-engineered drawing for your signature before steel is cut, and we mark the points where the new part deliberately differs from the worn original - usually the seal groove, the cushion or the pin bush.

Which mounting tolerates the worst alignment?

A pivoting one: eye with a spherical bush, clevis or trunnion. With a rigid foot or flange, alignment error goes into the rod and then into the seal lip and the guide bushing, which is where it shows up as a leaking cylinder after three months. Never shim a rigid mounting to force it true.

Is there a standard for medium-duty tie-rod cylinders?

ISO 10763 covers the metric series for medium-duty tie-rod cylinders, while ISO 6020 governs the mountings and ports they use. Naming the standard is only useful together with bore, rod, stroke and pressure; a quotation built from a standard number alone leaves the dimensions that matter unstated.

What test comes with a cylinder?

Proof and leak test at 1.5 times rated pressure on a nitrogen-purged rig, with the signed sheet recording pressure, hold time and result per serial number in the shipment file. Cushion setting, port thread gauging and the bore, rod and stroke dimensional report travel with it.

Fit this to a real part

Send the drawing and the answer comes back with your numbers

The quotation for hydraulic cylinders repeats this comparison against your grade, dimension, tolerance and test package, and names any deviation before production starts.

Ask about this specificationHydraulic Cylinders category hub

How we verify it

  • Grade and condition checked against the EN 10204 3.1 certificate and the heat marking.
  • Boundary dimensions, class, clearance or rating measured on the inspection sheet.
  • Deviations offered in writing before production, never discovered after shipment.

Trading and sourcing company based in northern Xingtai, Hebei, about 60 km south of the provincial capital. We buy across the industrial clusters of central and southern Hebei and reach the northern ones on scheduled factory runs; the supplier visits, benchmarking and pre-shipment inspection are ours, done in person. Not a factory. Multi-category, quoted from drawings, consolidated into one container and one document pack, and inspected before the balance is paid; every order starts as an RFQ.

Inspection and documents →

Written first reply within 1 working day; priced answer within 2-5 working days.

Quote it against your part, not the chart

Send the drawing, the standard your engineer named and the quantity. We reply with the priced specification, the substitution we recommend and why, and the inspection plan that proves it.