The mounting decides three things before the bore does: where the reaction load enters the machine, how much side load the rod sees, and how much misalignment the joint absorbs. Foot and flange mountings - the metric families of ISO 6020-1 and ISO 6020-2 - are rigid and demand alignment. Eye, clevis and trunnion mountings pivot, so they self-align but load a pin that must be sized for it.
Bores are not free choices either. The metric line-mounting family runs on the ISO 3302-1 bore series - 40, 50, 63, 80, 100, 125, 140, 160, 180, 200 mm - with rod diameters from the ISO 3302-2 preferred-number series. Move to the neighbouring bore and the tube, gland, port position and mounting all change, so a substitution is never cosmetic.
The mistake we see most often is a rigid mounting bolted to a bracket that flexes: the cylinder binds, the gland wears on one side, and the seal kit dies inside a season. Send the mounting face and the mating structure drawing, and the quotation flags the alignment and pin-sizing consequences instead of discovering them on the machine.
Mounting families and what each one does with the load| Mounting family | How the load reacts | Alignment demand | Side load on the rod | Usual duty |
|---|
| Foot or block mounting | Bending in the mounting bolts, shear into the base | Faces must be coplanar and parallel within the machine tolerance | Poor - rigid | Presses, shears, fixed stations |
|---|
| Square flange, head end | Direct compression into the machine face | Bolts and face must run true | Poor - rigid | Clamping and feeding with an axial load path |
|---|
| Circular line flange, cap end | Compression into a round boss | Pilot or dowel location recommended | Poor - rigid | Machine tool and mill-type service |
|---|
| Single eye with spherical bush | Through the pin, in bearing | Absorbs a few degrees of angular error | Acceptable if the bush is sized | Loader links, tipping gear, pivoting frames |
|---|
| Clevis or tang | Two shear planes in the pin | Allows oscillation | Acceptable | Rod-end attachment on moving structures |
|---|
| Trunnion or pivot pin | Central pivot, tension into the tie rods | Moderate | Acceptable | Long-stroke oscillating applications |
|---|
Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.