Xingtai, Hebei · Hebei industrial clusters

Specification reference · updated 29 September 2026

How is a hydraulic rod-seal gland designed, and which standard fixes the grooves for the seal, the wiper and the back-up ring?

The gland is a machined interface with its own standards, not part of the seal catalogue. ISO 10294-3 and ISO 10294-4 publish groove dimensions and tolerances for general-duty and heavy-duty reciprocating rod seals, ISO 6194 covers wiper rings, ISO 7795 covers back-up rings used with elastomer rings, and ISO 5597 fixes the preferred bore and rod diameters every one of those tables is indexed against.

The gland is a machined interface with its own standards, not part of the seal catalogue. ISO 10294-3 and ISO 10294-4 publish groove dimensions and tolerances for general-duty and heavy-duty reciprocating rod seals, ISO 6194 covers wiper rings, ISO 7795 covers back-up rings used with elastomer rings, and ISO 5597 fixes the preferred bore and rod diameters every one of those tables is indexed against.

A rod gland normally carries three elements, each with its own dimensional family: the pressure-loaded rod seal, a wiper in its own groove outboard of it, and on the pressure side an elastomer ring with a back-up ring to close the extrusion gap. ISO 10294-2 sorts the duty - pressure, rod speed and stroke - into general and heavy classes, and the groove table you may use depends on which class the circuit falls into.

Two naming traps sit on top of that. The bolted port families (ISO 6142 and ISO 6151 with 24° and 30° seats, ISO 6149 with an O-ring on the face) dimension connections, not seal glands, and are quoted as if they set groove depth. And no standard number carries a size: bore and rod come from the ISO 5597 series first, because a non-preferred rod turns every published groove table into an unusable column.

What each element of a rod-seal gland is dimensioned against - numbers read from the table for your bore, rod and duty class
Gland elementStandard that dimensions itWhat the standard fixesWhat must be on your drawingHow it fails when mismatched
Rod seal, general dutyISO 10294-1 and -2 (vocabulary, duty), groove per ISO 10294-3Groove diameter and width with their tolerance positions for the seal familyBore and rod from ISO 5597, the duty class, then the groove from the table for that sizeToo shallow leaks on low pressure and on reversal; too deep lifts the lip off the rod
Rod seal, heavy dutyISO 10294-2 (duty), groove per ISO 10294-4The heavier groove family for higher pressure, longer stroke and higher rod speedWorking and peak pressure plus the extrusion clearance you can actually holdThe lip rolls, then cuts at the gland parting line - the rubber looks chewed, not old
Wiper / scraper ringISO 6194 (styles 1, 2 and 3)Wiper cross-section and its groove and housing diameter seriesStyle, the rod diameter it clears, and the fact that it sits outboard of everythingScale and slurry ride past the pressure seal and score the chrome within a season
Elastomer ring with back-up ringISO 3601-1 (rings), ISO 3601-3 (gland), ISO 7795-1 and -2 (back-up rings)Ring size series with tolerances, gland fill, compatible back-up ring dimensionsPressure band, gap height, and whether one or two back-up rings are fittedThe ring extrudes into the clearance and is cut into a strip; it reads as bad rubber
Piston seal and bore glandISO 10294 family for the duty, ISO 3601-3 for static bore glandsBore-side groove geometry and the squeeze that goes with the bore toleranceFinished bore diameter and its tolerance class, measured on the tube, not nominalA bore out of round by a tenth of a millimetre changes the squeeze along the stroke
Bolted port and stud portISO 6142, ISO 6151, ISO 6149Port and stud-port geometry for 24° and 30° seats or an O-ring on the faceThe connection only - it has nothing to do with the seal grooveCited on a gland drawing as if it dimensioned the groove depth
Preferred bore and rod diametersISO 5597The cylinder bore and rod diameter series the seal and groove tables run onThe size you will machine to, before any seal enquiryAn off-series rod leaves every published groove table unusable and the seal becomes a moulded one-off

Values are the published minima, maxima or bands of the standards named in the table, taken at the stated thickness, size or temperature. Where a standard tabulates a value by size band, the value for your goods comes from the mill or test certificate, which we attach to the quotation instead of summarising it here.

Where this costs money

Three situations where the difference becomes a claim

Each is a decision taken at quotation stage, while the specification is still cheap to change.

The enquiry says "the same seal as the old cylinder"

The marking on a removed seal tells you almost nothing useful. What decides the replacement is the measured rod diameter, the measured gland depth and width, the bore, the working and peak pressure, rod speed, stroke, temperature and medium. We ask for those seven numbers on the RFQ and put them on the inspection sheet with the groove we measured on your housing.

The rod is re-chromed and put back

Hard chromium is built up in a layer, so a re-plated rod is a few hundredths larger than the drawing unless it is ground back to size. Squeeze rises with it, lip friction and temperature rise with the squeeze, and the wiper lip no longer clears correctly. State the finished rod diameter after plating on the work order and measure it before the seal is ordered.

A buffer ring is confused with cushioning

Back-up rings and elastomer elements in the gland handle extrusion; decelerating the piston at end of stroke is a cushioning arrangement designed into the cylinder, with its own throttle or fixed cushion piston. No seal groove standard covers it. If the machine is hammering its ends, that is a cylinder design question to put to the builder, not a seal to order.

Questions buyers ask before they commit the specification

Which standard actually dimensions a rod-seal groove?

For reciprocating rod seals, ISO 10294-3 for general duty and ISO 10294-4 for heavy duty, with ISO 10294-2 deciding which duty you are in. Wiper grooves are ISO 6194, back-up rings for elastomer rings are ISO 7795, and O-ring glands are ISO 3601-3. Check the edition each supplier quotes from: the port series ISO 6142 and ISO 6151 is a different subject and is often mis-cited for glands.

How deep should the gland be?

Out of the table for your seal cross-section and duty class, with its tolerance position respected, not from a rule of thumb. Moulded elastomer elements are typically installed with roughly 15-25 % compression and a gland no more than about 85-90 % full; lip seals are dimensioned from the ISO 10294 groove depth for the size. The tolerance on that depth matters as much as the nominal figure, because it is what sets the squeeze.

Can one rod seal take pressure from both directions?

Only if it is a double-acting element. A single-acting lip seal is pressed onto the rod by pressure on its own side; put pressure behind the other side and the lip unloads and leaks. Two single-acting seals back to back is a legitimate answer, but the trapped space between them has to be vented, otherwise it becomes a hydraulic lock that blows the seals out on the first stroke.

What surface finish does the gland need?

Practice commonly puts the rod sealing land at Ra 0.2-0.4 µm and the groove faces at Ra 1.6 µm or better, with a lead-in chamfer on the bore and a radius on the rod entry so the lip is not rolled during assembly. Confirm the figures against the gland tables of ISO 10294-3 or -4 and record what you measured, because a polished rod with a machined groove is a common and leaking combination.

Do you keep these seals in stock?

We buy to the generic designation you specify - standard, size, duty class, compound and hardness - and consolidate them with the rest of your order. No brand channel is held or implied; our documents state the ISO 1629 compound code, the size and the measured gland, and the inspection sheet carries the numbers rather than a catalogue part number.

Fit this to a real part

Send the drawing and the answer comes back with your numbers

The quotation for seals & gaskets repeats this comparison against your grade, dimension, tolerance and test package, and names any deviation before production starts.

Ask about this specificationSeals & Gaskets category hub

How we verify it

  • Grade and condition checked against the EN 10204 3.1 certificate and the heat marking.
  • Boundary dimensions, class, clearance or rating measured on the inspection sheet.
  • Deviations offered in writing before production, never discovered after shipment.

Trading and sourcing company based in northern Xingtai, Hebei, about 60 km south of the provincial capital. We buy across the industrial clusters of central and southern Hebei and reach the northern ones on scheduled factory runs; the supplier visits, benchmarking and pre-shipment inspection are ours, done in person. Not a factory. Multi-category, quoted from drawings, consolidated into one container and one document pack, and inspected before the balance is paid; every order starts as an RFQ.

Inspection and documents →

Written first reply within 1 working day; priced answer within 2-5 working days.

Quote it against your part, not the chart